Medical Device CNC Machining — ISO 13485 Certified.

From PEEK spinal cages to Ti-6Al-4V bone screws and 316L surgical instruments — Baosheng is the ISO 13485 certified CNC machining manufacturer that delivers biocompatibility documentation, full DHR traceability, and cleanroom-ready packaging. Every time.

  • ISO 13485:2016
  • ISO 10993 biocompatibility
  • Full DHR traceability
  • Cleanroom packaging
  • 2-hour certified quote
// PRECISION METRICS
  • Tightest tolerance:± 0.002 mm
  • Surface finish (Ra):0.1 μm achievable
  • CMM inspection:100% critical dims
  • Traceability:Heat lot → finished part
Ti Grade 23 ELI
ISO 5832-3 · AMS 4930
PEEK Optima®
ISO 13179 · Victrex
316L SS
ISO 5832-1 · ASTM F138
Co-Cr-Mo
ISO 5832-12 · ASTM F75
Ti-6Al-4V ELI
ISO 5832-3 · AMS 4928
PEEK-OPTIMA HA
Hydroxyapatite filled

ISO 13485:2016 · ISO 9001:2015 · ISO 10993 · IATF 16949

ISO 13485
Medical device QMS certified
6+
Implant-grade materials
Ra 0.1μm
Implant surface finish
100%
DHR traceability
Medical Standards
ISO 13485:2016 ISO 9001:2015 ISO 10993 biocompatibility Full DHR documentation Cleanroom packaging NDA before file review

ISO 13485 Certification — What It Actually Covers

ISO 13485 is not a “better ISO 9001.” It’s a fundamentally different QMS framework designed specifically for medical device supply chains — with requirements for traceability, risk management, and sterile barrier protection that commercial CNC suppliers don’t carry.

Work environment control
Documentation of environmental conditions affecting product quality. Temperature, humidity, and particulate monitoring where required for device class. Documented for each lot in the Device History Record.
Production process control & traceability
Every production step documented with operator ID, machine ID, date/time, and measurement results. Raw material lot tied to finished device serial number. Chain of custody maintained from raw billet to packaged component.
Contamination control
Documented procedures for prevention of contamination during machining, post-processing, and packaging. Separate handling paths for implant-grade and non-implant components. Coolant and lubricant biocompatibility documented where contact with implant surface occurs.
Non-conforming product handling
Non-conforming components are tagged, quarantined, and dispositioned via formal NCR process before any batch is released. Corrective action root-cause documented. Customer notification within 24 hours of detection on released product.
Customer communication — design review
Written DFM review issued before production start identifies biocompatibility risks, surface finish requirements, sterilization compatibility, and tolerance feasibility. Design review documented and retained as part of the DHR.
ISO 13485:2016
Medical Device QMS
Full quality management system for design, production, installation, and servicing of medical devices. Annual third-party audit. Scope covers CNC machining and assembly of medical device components.
  • Primary cert
  • Annual audit
ISO 10993
Biocompatibility
Biological evaluation framework for materials in contact with human tissue or body fluids. Material selection, surface finish, and residual manufacturing substance documentation aligned to ISO 10993-1 risk assessment pathway.
  • Implant materials
  • ISO 10993-1
21 CFR Part 820
FDA QSR Alignment
Our ISO 13485 QMS is aligned to the FDA Quality System Regulation. DHR documentation supports 510(k) and PMA regulatory submissions. Documentation available in FDA-compatible formats on request.
  • 510(k) support
  • PMA ready
MDR 2017/745
EU Medical Device Reg.
Material traceability and biocompatibility documentation aligned to EU MDR requirements. UDI-compatible lot traceability. CE marking technical file support documentation available.
  • EU MDR
  • UDI compatible
Baosheng ISO 13485 certified medical device CNC machining — quality documentation including DHR and biocompatibility records

Implant-Grade & Medical CNC Materials

Not every material grade is appropriate for medical device use. The difference between “stainless steel” and “ASTM F138 implant-grade 316L SS” is the difference between biocompatibility and a regulatory failure. Here’s what we stock and why each grade matters.

Ti Grade 23
// Ti-6Al-4V ELI · ISO 5832-3
  • Tensile strength:860 MPa
  • Biocompatibility:Excellent
  • Corrosion resistance:Excellent
  • Machinability:Difficult
Applications: bone screws · spinal cages · hip stems · trauma plates · dental implants · orthopaedic fixtures
 
ELI = Extra-Low Interstitial — reduced O₂, N₂, C, Fe for superior fracture toughness in implant service. ISO 10993 compliant.
PEEK Optima®
// ISO 13179-1 · Victrex LT1
  • Tensile strength:100 MPa
  • Radiolucency:Radiolucent
  • Service temp.:250 °C
  • Machinability:Moderate
Applications: spinal fusion cages · total disc replacement · cranial implants · structural orthopaedic components
 
Radiolucent — does not artifact on MRI or CT. Elastic modulus closer to cortical bone than titanium (reduces stress shielding).
316L Stainless
// ASTM F138 · ISO 5832-1
  • Tensile strength:485 MPa
  • Corrosion resistance:Excellent
  • Passivation:ASTM A967
  • Machinability:Moderate
Applications: surgical instruments · retractors · trocars · laparoscopic tools · non-implant device housings · dental instruments
 
ASTM F138 is the implant-specific grade — lower carbon content (C < 0.03%) prevents sensitization at surgical sterilisation temperatures.
Co-Cr-Mo
// ASTM F75 / F799 · ISO 5832-12
  • Tensile strength:897 MPa
  • Wear resistance:Excellent
  • Hardness:HRC 35–40
  • Machinability:Very difficult
Applications: total knee femoral components · total hip heads · spinal disc arthroplasty · dental prosthetics · high-wear joint surfaces
 
Cobalt ion release is a known concern in total arthroplasty. Surface finish Ra ≤ 0.025μm required on articulating surfaces to minimise wear particle generation.
Ti Grade 4
// CP Titanium · ASTM F67
  • Tensile strength:550 MPa
  • Osseointegration:Excellent
  • Purity:CP (vanadium-free)
  • Machinability:Moderate
Applications: dental implants · abutments · dental crowns · orthopaedic screws · hearing implant housings
 
Vanadium-free — preferred for dental applications where V leaching has been studied. Highest biocompatibility of all commercial titanium grades.
UHMWPE
// GUR 1020/1050 · ISO 5834-2
  • Mol. weight:>3.5M g/mol
  • Wear resistance:Excellent
  • Impact resistance:Excellent
  • Machinability:Good
Applications: total knee tibial inserts · total hip acetabular liners · spinal disc nucleus · shoulder glenoid components
 
Must specify Ticona GUR 1020 or GUR 1050 medical-grade resin. Cross-linked (XLPE) variants available on request for reduced oxidation in vivo.

Biocompatibility & Regulatory Compliance Matrix

MaterialISO 10993 compliantASTM / ISO standardImplant contactBlood contactMRI compatibleSterilization
Ti Grade 23 ELI✓ YesISO 5832-3✓ Yes✓ Yes✓ ConditionalAll methods
PEEK Optima®✓ YesISO 13179-1✓ Yes✓ Yes✓ RadiolucentAutoclave / EO / gamma
316L SS (F138)✓ YesASTM F138✓ Short-term✓ Yes△ Artifact possibleAutoclave / EO
Co-Cr-Mo (F75)✓ YesASTM F75✓ Long-term✓ Yes△ Artifact possibleAutoclave / EO / gamma
Ti Grade 4 CP✓ YesASTM F67✓ Yes✓ Yes✓ ConditionalAll methods
UHMWPE (GUR)✓ YesISO 5834-2✓ Long-term✗ Not recommended✓ RadiolucentGamma / EO (not autoclave)

Specify your device class and contact duration when requesting a quote — we’ll confirm material selection against ISO 10993 risk assessment pathway.

Medical Device Components We Machine

Every device class has distinct precision, surface finish, and documentation requirements. Here’s how our CNC capability maps to the major medical device subsystems.

CNC machined titanium orthopaedic implants — bone screws, spinal fusion cages and trauma plates
Class III · Implantable
Orthopaedic Implants
Bone screws, spinal fusion cages, trauma plates, intramedullary nails, hip stems, and knee components. Full DHR, lot-specific mill certs, and biocompatibility documentation required on every lot.
  • Materials:Ti ELI · Co-Cr · PEEK
  • Surface Ra:0.1–0.4μm implant
  • Tolerance:±0.005–0.010mm
  • Sterilization:All methods compatible
CNC machined 316L stainless surgical instruments with mirror polish finish for autoclave sterilization
Class II · Reusable / Disposable
Surgical Instruments
Scissors, retractors, trocars, laparoscopic graspers, and endoscopic components. Surface finish critical for cleanability. Autoclave compatibility requires specific material and finishing specifications.
  • Materials:316L SS · 17-4 PH
  • Surface Ra:≤0.4μm (cleanable)
  • Passivation:ASTM A967 / AMS 2700
  • Sterilization:Autoclave 134°C
CNC machined titanium Grade 4 dental implants and abutments with precision surface finish
Class IIb · Implantable
Dental Implants & Prosthetics
Dental implant fixtures, abutments, healing caps, and CAD/CAM prosthetic components. Surface texture requirements (SLA, machined) affect osseointegration rate — our DFM review includes surface strategy guidance.
  • Materials:Ti Grade 4 · Zirconia
  • Thread tolerance:ISO 6g/6H precision
  • Hex interface:±0.003mm
  • Surface:Machined / SLA
CNC machined aluminum medical imaging device housings with anodized finish
Class I / IIa · Device housing
Imaging & Diagnostic Devices
Ultrasound transducer housings, MRI coil frames, CT detector mounts, and endoscope handles. Non-magnetic materials required for MRI applications. Electrical grounding paths often integrated into structural components.
  • Materials:Al 6061 · PEEK · Delrin
  • MRI compatibility:Non-magnetic verified
  • Tolerance:±0.025mm housing
  • Finish:Anodize / chem-film
CNC machined medical drug delivery device components in titanium and PEEK
Class II / III · Combination device
Drug Delivery Devices
Auto-injector mechanisms, pump housings, insulin pen components, intravascular catheter tips, and microfluidic manifolds. Drug contact surfaces require specific materials and extractable/leachable documentation under ISO 10993-18.
  • Materials:316L · PEEK · Ti
  • E&L documentation:ISO 10993-18
  • Surface Ra:≤0.2μm drug contact
  • Passivation:ASTM A967 required
Tight Tolerance CNC Machining
Class IIa · Wearable / Implantable
Wearables & Minimally Invasive
Continuous glucose monitor housings, cardiac monitor enclosures, robotic surgery tool tips, and laparoscopic instrument components. Miniaturisation is the challenge — features <0.5mm require micro milling strategies. Small batch friendly — no MOQ.
  • Min feature:<0.5mm (micro mill)
  • Materials:Ti · PEEK · 316L
  • Lot size:1 prototype to 10K+
  • IP protection:NDA standard

Device History Record — How We Build Yours

The DHR is the backbone of FDA 21 CFR 820.184 compliance. Here’s how we build a complete, audit-ready DHR for every medical device component we manufacture.

Design input review & DFM
Engineer reviews drawing, material spec, device class, sterilization method, and biocompatibility requirements. Design review documented. Risk items flagged. DFM report issued in writing within 2 hours.
  • Design review record
  • DFM report
Material verification & traceability
Incoming material lot verified against EN 10204 3.1 or 3.2 mill certificate. Chemical composition and mechanical properties confirmed against ASTM/ISO specification. Heat number recorded on job traveller — tied to your order and device serial number.
  • Mill certificate
  • Incoming inspection record
In-process records & SPC
Operator ID, machine ID, date/time, tool lot, and measurement results recorded at each operation. First-article verified before batch continues. SPC applied on critical characteristics — any out-of-control condition triggers immediate work-stop.
  • In-process records
  • SPC charts
CMM dimensional inspection
100% CMM measurement of all critical GD&T callouts. Temperature-stabilised measurement room. Actual vs. nominal report generated per-part or per-batch. Non-conforming parts quarantined — NCR raised and dispositioned before batch released.
  • CMM dimensional report
  • NCR records (if any)
Cleanroom packaging & labelling
Implant-grade and sterile-barrier components packaged per device class requirements. Cleanroom (ISO Class 7 equivalent) packaging area for implant components. Lot number, material, expiry date, and sterilisation instructions on primary label where required.
  • Packaging inspection record
  • Label verification
Shipment with complete DHR package
Full DHR package — mill cert, CMM report, in-process records, NCR disposition (if any), packaging inspection, and Certificate of Conformance — enclosed with shipment. Digital copy emailed at dispatch. Records retained for device lifetime + 2 years minimum.
  • Certificate of Conformance
  • Full DHR package

Medical CNC Supplier Comparison

RequirementBaosheng General CNC supplier
ISO 13485 certification
Certified, annual audit
Not certified
Full DHR documentation
Standard, every order
Not standard
Implant-grade material stock
In stock, 6+ grades
Not stocked
Biocompatibility docs
ISO 10993 aligned
Not available
Cleanroom packaging
ISO Class 7 available
Not available
CMM inspection report
100% critical dims
Spot check only
PEEK Optima machining
Dedicated protocols
Commercial PEEK only
NDA before file review
Standard, same day
On request
10-year record retention
QMS mandated
Not guaranteed

NDA signed before file review · 2-hour response

Surface Finishing for Medical Device Components

Surface finish in medical devices is not an aesthetic choice — it determines cleanability, osseointegration, corrosion resistance, and sterilization compatibility. Here’s the clinical rationale behind each finish specification.

Standard implant finish
Ra ≤ 0.4μm — Machined
// As-machined, fine passes · Standard surgical instrument finish
  • Required for cleanable surgical instruments (EN ISO 17664)
  • Achievable on stainless 316L and titanium with single finishing pass
  • Autoclave compatible — no special finishing required
  • Baseline requirement for most Class I/II device surfaces
  • Verify on drawing: “Ra ≤ 0.4μm on all external surfaces”
Implant articulating surfaces
Ra ≤ 0.025μm — Mirror Polish
// Hand polished · Diamond compound · Electropolish option
  • Required for articulating joint surfaces (knee, hip, spine disc)
  • Reduces wear particle generation — critical for Co-Cr-Mo
  • Electropolishing achieves Ra ≤ 0.1μm on stainless in bores
  • Full surface: manual diamond compound + vibratory finishing
  • Specify: Ra value, measurement direction, and reference standard
Bone contact / osseointegration
SLA — Sandblasted Acid Etched
// Sa 1.0–2.0μm · Controlled roughness · Ti surfaces only
  • Promotes osseointegration — increases bone cell attachment area
  • Applied to titanium implant surfaces in contact with bone
  • Process: Al₂O₃ bead blast → HCl/H₂SO₄ acid etch
  • ISO 14434 surface characterisation documentation
  • NOT applied to articulating, threading, or precision-fit surfaces
Corrosion protection
Passivation
// ASTM A967 / AMS 2700 · 316L and 17-4 PH SS
  • Removes free iron from stainless surface — forms passive chromium oxide layer
  • Critical for 316L surgical instruments — prevents rust in autoclave
  • Citric acid (ASTM A967 Method C) — environmentally preferred over nitric
  • Tested per ASTM A967 — water immersion test or salt spray
  • Dimension change: negligible (<0.0001mm) — no tolerance impact
Anodizing for titanium
Anodic Oxidation (Type II)
// Colour-coded implants · Ti identification · ASTM F86
  • Colour codes implant sizes without paint — critical for OR identification
  • Improves corrosion resistance of titanium in physiological environment
  • Does NOT improve osseointegration — SLA is used for that
  • ASTM F86 standard for anodising surgical implants
  • Dimensional change: +1–5μm per side — flag tight-tolerance features
PEEK post-processing
Plasma Activation (PEEK)
// PEEK Optima surface treatment · HA coating prep
  • Modifies PEEK surface energy — improves bone cell adhesion
  • Required before hydroxyapatite (HA) coating deposition
  • Argon / oxygen plasma treatment — no dimensional change
  • Increases wettability from >70° contact angle to <10°
  • Available for PEEK-OPTIMA HA Enhanced grade preparation
Material / FinishSteam autoclave (134°C)Ethylene oxide (EO)Gamma irradiationElectron beam (e-beam)Hydrogen peroxide plasma
Ti Grade 23 ELI✓ Excellent✓ Compatible✓ Compatible✓ Compatible✓ Compatible
PEEK Optima® (neat)✓ Up to 134°C✓ Compatible△ Oxidation risk△ Verify dose✓ Compatible
316L SS (passivated)✓ Excellent✓ Compatible△ Check grade✓ Compatible✓ Compatible
Co-Cr-Mo (F75)✓ Excellent✓ Compatible✓ Compatible✓ Compatible✓ Compatible
UHMWPE (GUR 1020)✗ Degrades✓ Compatible△ XLPE preferred✓ Compatible✓ Compatible
Anodised Ti✓ Stable✓ Compatible✓ Compatible✓ Compatible✓ Compatible

Every Document Your Regulatory Submission Needs

Medical device regulatory submissions live and die on documentation completeness. Here’s every deliverable Baosheng provides — and the standard it conforms to.

Mill Certificate
EN 10204 Type 3.1 / 3.2 · ASTM / ISO spec
Chemical composition, mechanical properties, heat number. Issued by raw material mill — not a distributor copy. Type 3.2 (independent inspection authority) available on request.
  • Included with every order
CMM Inspection Report
ISO 10360 · Per-part or batch statistical
Actual vs. nominal for every GD&T callout. Zeiss/Renishaw CMM, accuracy ±0.0008mm. Temperature-stabilised room. Probe calibration records attached.
  • 100% critical dimensions
Device History Record
FDA 21 CFR 820.184 · ISO 13485 §7.5
Complete production record: operator ID, machine, tools, date/time, measurements. Material lot tied to device serial. Available for 10-year retention. FDA audit-ready format.
  • Standard on all medical orders
Certificate of Conformance
Signed declaration of conformity
Signed declaration that components meet drawing, material spec, and QMS requirements. References lot number, quantity, inspection results, and applicable standards. Issued by QA manager.
  • Included with shipment
Biocompatibility Declaration
ISO 10993-1 · ISO 10993-18
Material biocompatibility declaration referencing ISO 10993 risk assessment pathway. Residual manufacturing substances (coolants, lubricants) listed where device contact occurs. Available for implant and skin-contact applications.
  • On request for implant orders
First Article Inspection (FAI)
AS9102 / Customer-defined
Full dimensional report on first-off production part. Includes material verification, functional test results where applicable, and conformance statement. Required at new part number release and after engineering changes.
  • Standard on new part numbers

All documents delivered digitally with shipment. 10-year record retention in our QMS.

What Drives Medical Device CNC Machining Cost

Medical device CNC machining costs more than commercial parts — for clinically defensible reasons. Here’s the honest breakdown of every cost driver.

Implant-grade material premium
PEEK Optima® costs 15–20× more per kg than industrial PEEK. Ti Grade 23 ELI is 25–40% more expensive than Grade 5 Ti-6Al-4V due to tighter interstitial content controls. Co-Cr-Mo is among the most expensive machinable alloys. The premium is in the material, not the machining — and it’s non-negotiable for implant use.
  • Highest cost driver
Documentation & quality overhead
A commercial CNC part might have 5 minutes of inspection and documentation time. An ISO 13485 medical device component with full DHR, CMM, biocompatibility declaration, and CoC may require 60–120 minutes of quality overhead per lot. This is the cost of regulatory compliance — and it’s what makes the part certifiable.
  • High cost driver
Surface finish to Ra 0.1μm
Achieving Ra ≤ 0.1μm on implant articulating surfaces requires hand polishing with diamond compound — typically 20–60 minutes of manual labour per part. Mirror finishing on complex 3D surfaces (femoral condyles, spinal end plates) takes longer. Our DFM review identifies where mirror finish is clinically required vs where Ra 0.4μm is sufficient.
  • Medium-high cost
Machining difficult biomaterials
Co-Cr-Mo machinability index is approximately 25 (vs 100 for free-cutting steel). PEEK Optima® requires dedicated tooling and specific cutting parameters to avoid surface damage and residual stress. Both require process validation and dedicated tooling programs that add to unit cost at low quantities.
  • Medium cost driver
Cleanroom packaging
ISO Class 7 cleanroom packaging for implant components adds a controlled-environment packaging operation with gown protocol, particle monitoring records, and sterile barrier validation documentation. Per-unit cost is modest — but the infrastructure cost is real and reflected in pricing.
  • Lower cost driver
316L surgical instrument prototype (1–10 pcs)
From $45 / pc
316L SS · 3-axis · Ra ≤ 0.4μm · passivated · CMM report · mill cert · 3–5 day lead
Ti Grade 23 orthopaedic implant (1–5 pcs)
From $280 / pc
ELI titanium · 5-axis · Ra ≤ 0.4μm · full DHR · CMM 100% · biocompatibility doc · 7–10 day lead
PEEK Optima spinal cage (1–3 pcs)
From $380 / pc
Victrex PEEK-Optima · 5-axis · Ra ≤ 0.4μm · full DHR · ISO 13485 documentation · 8–12 day lead
Production run with DHR (50–500 pcs)
Volume pricing + full DHR package
Per-lot mill cert · SPC monitoring · CMM batch report · CoC · cleanroom packaging
Free Medical DFM Review — Every Quote
Our medical device DFM review covers surface finish vs. device class requirements, sterilization compatibility, biocompatibility risk, material selection for patient contact class, and documentation scope. Written report issued before you commit. Average DFM-driven savings on medical CNC: 15–30% per component.

CNC Machining Medical Device Components — Questions Answered

Are you ISO 13485 certified for medical device CNC machining?
 
Yes — Baosheng holds ISO 13485:2016 certification covering the design and manufacture of medical device components. Our QMS is audited annually by an accredited third-party body. Scope covers CNC machining, surface finishing, and assembly of implant-grade and non-implant medical device components. Certificate available on request.
Can you machine PEEK Optima® for spinal implants?
 
Yes — with Victrex PEEK-OPTIMA® implant-grade resin (LT1 or LT3), not industrial PEEK. We maintain dedicated tooling protocols for implant-grade PEEK to avoid surface damage, residual stress, and contamination. We do NOT substitute commercial PEEK for implant applications. Full material traceability from Victrex lot certificate to finished component.
What biocompatibility documentation do you provide?
 
We provide a material biocompatibility declaration referencing ISO 10993-1 risk assessment pathway for each implant-grade material. For drug-contact or skin-contact surfaces, an extractables and leachables (E&L) assessment per ISO 10993-18 is available. We document all manufacturing chemicals (coolants, lubricants) that contact device surfaces and confirm biocompatibility.
Do you provide Device History Records (DHR) for FDA compliance?
 
Yes — standard on all medical orders. Our DHR includes: operator and machine identification, material lot number, in-process measurement records, CMM inspection results, NCR disposition (if applicable), packaging inspection, and Certificate of Conformance. Format is compatible with FDA 21 CFR 820.184 audit requirements. Records retained for 10 years minimum.
What surface finish can you achieve on implant components?
 
Ra ≤ 0.025μm on articulating surfaces using diamond compound hand polishing. Ra ≤ 0.1μm on implant body surfaces via fine finishing passes. Ra ≤ 0.4μm standard on surgical instrument surfaces (EN ISO 17664 compliant). Specify your functional requirement — articulating, bone contact, instrument, or cosmetic — and we’ll confirm the appropriate finish strategy in the DFM review.
Can you machine Co-Cr-Mo for total joint replacement components?
 
Yes — ASTM F75 cast and ASTM F799 wrought Co-Cr-Mo are available. Co-Cr-Mo has a machinability index of approximately 25 — it requires dedicated carbide tooling, slow feed rates, and aggressive coolant management. Tool life is 3–5× shorter than stainless machining. This is reflected transparently in quoting. CMM verification of articulating surface dimensions and Ra measurement documentation included.
Do you offer cleanroom packaging for implantable components?
 
Yes — ISO Class 7 equivalent cleanroom packaging area for implant-grade components. Parts are visually inspected, cleaned per validated procedure, and packaged in double sterile barrier (Tyvek/film) with lot labelling. Packaging inspection records form part of the DHR. EO, gamma, and e-beam sterilization-compatible primary packaging available.
What is the minimum order for medical CNC machined components?
 
No minimum order quantity. We machine single prototypes and first-article components every day under full ISO 13485 documentation requirements. The quality overhead (DHR, CMM, CoC) applies to all quantities equally — which means the per-unit quality cost at 1 piece is higher than at 100 pieces, but every single prototype receives the same documentation standard as a production lot.

Medical Device CNC Machining. ISO 13485 Certified. DHR Ready.

Submit your medical device drawing. NDA signed before file review. Free DFM analysis. Certified quote with biocompatibility documentation in 2 hours.

✓ NDA before file review  ✓ ISO 13485 certified  ✓ Full DHR included  ✓ Biocompatibility docs  ✓ Cleanroom packaging  ✓ 2-hour quote